Volcano addressable system is a cutting-edge fire alarm solution designed to meet the highest safety standards. System consist of control panels with 1, 2, 4 loops, smoke detectors, heat detectors, gas detectors, manual call points, outdoor and indoor sounders, I/O modules. All detectors have short circuit protection and complies with the EN54 standards. 

Addressable Fire Detection Panel


Learn more

Addressable Detectors


Volcano addressable smoke and heat detectors are designed to detect smoke and heat in the area and are suitable for use with volcano addressable fire alarm panels. EAP and EAPE are designed in accordance with EN54-7 standard. The EAP product has short circuit protection and complies with the EN54-17 standard. EAH and EAHE are designed in accordance with EN54-5 standard. The EAH product has short circuit protection and complies with the EN54-17 standard.

 

Learn more

Addressable Manual Call Point


Volcano addressable manual call points are designed to detect fire by trigger alerts with pressing the transparent area on the button and are suitable for use with volcano addressable fire alarm panels. EAB20R and EAB20RE are designed in accordance with EN54-11 standard. The EAB20R product has short circuit protection and complies with the EN54-17 standard.

Learn more

Addressable Sounders


Volcano addressable system includes indoor and outdoor sounders. EASL is loop powered for indoor use with grade 2, environment class II, EASO is for outdoor use with grade 2, environment class IV. All sounders designed to give audible warnings, and are suitable to use with volcano addressable fire alarm panels. There are 4 different tone types. EASL, EASLE, EASO and EASOE is designed in accordance with EN54-3 standard. EASL and EASO products have short circuit protection and complies with EN54-17 standard.

Learn more

Addressable Modules


Volcano addressable system consist of different types of input and output modules. In the family there are input modules, relay modules, input and output modules and conventional modules. All modules have short circuit protection and complies with the EN54-17 and EN54-18 standard. Input modules, relay modules, input and output modules allow user to integrate various devices into the system. Conventional module enables the use of conventional devices with an addressable system. For input states, normal, open, short circuit, pre-alarm and alarm types can be selected. 

Learn more

Software for Addressable Fire System


The Volcano Addressable System offers three software options: Configuration Software, Graphical Monitoring Software, and Relay Programming Software. These tools are designed to simplify device configuration and monitoring for users.

Learn more